Why does the Intel® Stratix® 10 EMIF Toolkit report DQS Enable Calibration failure? - Why does the Intel® Stratix® 10 EMIF Toolkit report DQS Enable Calibration failure?
Description Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 19.3 and earlier, the Intel Stratix® EMIF Toolkit calibration report may show a DQS Enable Calibration failure even though both the DQ/DQS read and write margins show passing valid window values. This DQS Enable Calibration failure report can be ignored if the DQ/DQS read and write margins show passing valid window values. Resolution To work around this problem in the Intel® Quartus® Prime Pro Edition Software version 19.3 and earlier, you can also verify that the local_cal_success signal is asserted using the Signal Tap Logic Analyzer tool. This problem is fixed in the Intel Quartus Prime Pro Edition Software version 19.4 and later.
Custom Fields values:
['novalue']
Troubleshooting
14010574450
True
['External Memory Interfaces Stratix® 10 FPGA IP']
['FPGA Dev Tools Quartus® Prime Software Pro']
novalue
19.3
['Stratix® 10 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2021-08-25
external_document