Internal Error: Sub-system: PMB, File: /quartus/periph/pmb/pmb_module_gen7.cpp, Line: 1306; Cannot instantiate LSM_BF atom and other LSM atoms at same time - Internal Error: Sub-system: PMB, File: /quartus/periph/pmb/pmb_module_gen7.cpp, Line: 1306; Cannot instantiate LSM_BF atom and other LSM atoms at same time
Description Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 21.3, you may see this internal error when compiling a design that targets an Intel® Stratix® 10 device. This error occurs when there are no more LSM atoms available to reset the debug logic to a known state during power-up. Resolution To work around this problem, add an Intel® Configuration Reset Release Endpoint to Debug Logic IP from the Intel® Quartus® Prime Pro IP Catalog to the design . This means the IP must be created , added to the project , and instantiated in the design. This IP can be found in Intel® Quartus® Prime Pro by navigating in the IP Catalog to Library > Basic Functions > Simulation; Debug and Verification > Debug and Performance . Connect the conf_reset input of this IP to a post-configuration reset signal to ensure that debug logic on the device operates from a reliable initial state. This problem is fixed starting with Intel® Quartus® Prime Pro Edition Software version 22.1.
Custom Fields values:
['novalue']
Troubleshooting
16014176504
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
22.1
21.3
['Stratix® 10 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2023-01-04
external_document