RapidIO II IP Core Hangs After Receiving MAINTENANCE Read Response With DONE Status but No Payload - RapidIO II IP Core Hangs After Receiving MAINTENANCE Read Response With DONE Status but No Payload
Description When the RapidIO II IP core receives a MAINTENANCE read response with DONE status but without a payload, the IP core should indicate an error. However, the IP core hangs. Refer also to RapidIO II IP Core Does Not Return ERROR Response Packet to MAINTENANCE Request with Illegal Size . Resolution This issue has no workaround. This issue is fixed in version 14.0 of the RapidIO II MegaCore function.
Custom Fields values:
['novalue']
Troubleshooting
novalue
True
['novalue']
['FPGA Dev Tools Quartus II Software']
14.0
12.1
['Programmable Logic Devices']
['novalue']
['novalue']
['novalue'] - 2021-08-25
external_document