Does the HDMI IP meet the specification requirement of a Minimum 12 Control Period Symbols? - Does the HDMI IP meet the specification requirement of a Minimum 12 Control Period Symbols? Description The HDMI TX IP core in any configuration with audio support does not always guarantee minimum duration control period of 12 symbols as per HDMI 1.4b (Table 5-3) specification requirement. In any video resolution that fulfills the following horizontal blanking (Hblank) condition potentially violates the requirement of minimum 12 control period symbols. Hblank = (X * 32 Y) 56 48 where X = 0, 1, 2, 3, 4, 5, 6, 7, 8, … Y = 0, 1. Y = 0 leaves the following control period at only 10 symbols while Y = 1 leaves the following control period at only 11 symbols. Not being fully compliant to specification could potentially cause interoperability issues. Resolution There is no work around for this problem. This problem will be fixed in a future release of the Quartus® Prime software. Custom Fields values: ['novalue'] Troubleshooting FB: 471100, 470404; True ['HDMI IP'] ['FPGA Dev Tools Quartus® Prime Software Pro'] novalue 14.1 ['Programmable Logic Devices'] ['novalue'] ['novalue'] ['novalue'] - 2021-08-25