Should I follow both ‘Required specification’ if I cannot follow the ‘Recommended specification’ for powering-down Intel® Cyclone® 10 GX, Intel® Arria® 10, and Intel® Stratix® 10 devices as described in AN 692 document? - Should I follow both ‘Required specification’ if I cannot follow the ‘Recommended specification’ for powering-down Intel® Cyclone® 10 GX, Intel® Arria® 10, and Intel® Stratix® 10 devices as described in AN 692 document? Description Yes, users must follow both ‘Required specification’ if you cannot follow the power-down sequence recommended specification. You must ensure all power rails fully power down within 100ms with following requirements: a. Required Power-Down Ramp Specification – all Group 2 and Group 3 supplies must be under 1.0V whenever any Group 1 supply goes under 0.35V. You can refer to AN 692 document for the different power groups. AND b. Required Voltage Differential Specification – any two power supplies between different power groups during power-down is meeting the voltage differential specification: ΔV < ΔVnom 500 mV Custom Fields values: ['novalue'] Troubleshooting FB: 564189; False ['novalue'] ['novalue'] novalue novalue ['Arria® 10 FPGAs and SoCs', 'Cyclone® 10 GX FPGA', 'Stratix® 10 FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2021-08-25