Warning Message Indicates RapidIO IP Core Preliminary Support for Arria V, Cyclone V, and Stratix V Devices - Warning Message Indicates RapidIO IP Core Preliminary Support for Arria V, Cyclone V, and Stratix V Devices
Description The RapidIO MegaCore function v13.0 SP1 and later provides final support for Arria V, Cyclone V, and Stratix V devices. However, when your RapidIO MegaCore function targets one of these devices, a warning message indicates support is only preliminary. This warning message is erroneous. This issue has no design impact. You can ignore this warning message. Resolution This issue has no workaround. This issue is fixed in version 14.0 of the RapidIO MegaCore function.
Custom Fields values:
['novalue']
Troubleshooting
novalue
True
['novalue']
['FPGA Dev Tools Quartus II Software']
14.0
13.0.1
['Programmable Logic Devices']
['novalue']
['novalue']
['novalue'] - 2021-08-25
external_document