Does the Pairs only option work correctly in Timing Analyzer? - Does the Pairs only option work correctly in Timing Analyzer?
Description No, due to a problem in the Quartus® Prime Pro Edition Software version 24.3, you might see that not all paths are reported when the Pairs only option is enabled. This problem only occurs when reporting multiple corners. The following reports are affected - get_timing_paths report_timing report_timing_tree report_design_metrics report_neighbor_paths report_logic_depth report_exceptions report_timing_by_source_files The slacks reported in the Timing Analyzer summaries are correct. Resolution To work around this problem, don't use the Pairs only option or report just one corner at a time. This problem is scheduled to be fixed in a future release of the Quartus® Prime Pro Edition Software.