Error: no such variable (read trace on "::env(IP_ROOTDIR)") - Error: no such variable (read trace on "::env(IP_ROOTDIR)")
Description Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 18.1, you might receive the following error message when generating the eSRAM Intel® FPGA IP core. Error: no such variable (read trace on "::env(IP_ROOTDIR)") Resolution To work around this problem, ensure the Windows* environment variable "IP_ROOTDIR" to "%QUARTUS_ROOTDIR%\..\ip\" is set. This problem is fixed starting with the Intel® Quartus® Prime Pro/Standard Edition Software version 19.2
Custom Fields values:
['novalue']
Troubleshooting
FB: 599833;
False
['Memory Models']
['FPGA Dev Tools Quartus® Prime Software Pro']
19.2
18.1
['Stratix® 10 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2023-03-09
external_document