Error (209014): CONF_DONE failed to go high in device <number> - Error (209014): CONF_DONE failed to go high in device <number>
Description Due to an issue in the Quartus® Prime software version 16.1.1 and earlier, you may observe this error in the Quartus Prime programmer when programming MAX® 10 devices with date code 1625 and onwards, using the following sequence: Full-chip erase --> SOF configuration --> Power cycle/pulse nCONFIG --> SOF/POF programming. Resolution This issue is fixed in Quartus Prime software version 16.1.2.
Custom Fields values:
['novalue']
Troubleshooting
FB: 415920;
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Standard']
16.1.2
15.1.2
['MAX® 10 10 FPGAs']
['Stand-Alone Programmer 10.23 (For Legacy Max+Plus® II Software)']
['novalue']
['novalue'] - 2021-08-25
external_document