Why does the factory fall back mechanism not work when Direct to Application Mode is used in the Intel® Arria® 10 FPGA devices? - Why does the factory fall back mechanism not work when Direct to Application Mode is used in the Intel® Arria® 10 FPGA devices?
Description When using Direct to Application (DTA) mode in the Intel® Arria® 10 FPGA devices, in order for the Factory fall back mechanism to work, you must enable the ‘Auto-restart configuration after error’ project option under the following menu: Assignments > Device > Device and Pint Options > General > Auto-restart configuration after error Resolution This information is scheduled to be included in a future release of the Remote Update Intel® FPGA IP User Guide.