Unable to establish a connection because no memory interface targets exist on the linked device. - Unable to establish a connection because no memory interface targets exist on the linked device. Description When using the External Memory Interface (EMIF) Toolkit in the Intel® Quartus® Prime Software version 19.1 or later, you may see this error message if you try to run the Create Memory Interface Connection command. Resolution To work around this error message, verify that the Intel® Quartus® Prime Software project contains the .qsf, .qpf, and .sof files in the working directory. These files are the minimum file set to run the EMIF Toolkit. Custom Fields values: ['novalue'] Troubleshooting 14010376952 False ['External Memory Interfaces Arria® 10 FPGA IP', 'External Memory Interfaces Stratix® 10 FPGA IP'] ['FPGA Dev Tools Quartus® Prime Software Pro'] novalue 19.1 ['Arria® 10 FPGAs and SoCs', 'Cyclone® 10 FPGAs', 'Stratix® 10 FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2023-05-16