Is there any change in the Intel® Stratix® 10 / all Intel Agilex® Smart VID PMBus Slave Mode handshake flow in the Intel® Quartus® Prime Pro Edition Software version 21.1? - Is there any change in the Intel® Stratix® 10 / all Intel Agilex® Smart VID PMBus Slave Mode handshake flow in the Intel® Quartus® Prime Pro Edition Software version 21.1?
Description Yes, in the Intel® Quartus® Prime Pro Edition Software version 21.1, the behavior of the PWRMGT_ALERT signal in the handshake flow for Intel® Stratix® 10 / all Intel Agilex® FPGA Smart VID PMBus Agent Mode has been changed. This signal will be asserted in the first configuration cycle to inform the PMBUS host that a voltage change is required. If you perform a second or subsequent configuration without a power cycle, the PWRMGT_ALERT signal will not be asserted if the bitstream has the same VID setting specified in the Intel Quartus Prime Software project and the same configuration firmware. The PWRMGT_ALERT signal will still be asserted when there is any I2C/PMBus error. It will not be asserted during Partial Reconfiguration. Resolution Starting with the Intel® Quartus® Prime Pro Edition Software version 21.2, the PWRMGT_ALERT signal will be asserted for the first configuration and subsequent configuration as per behavior prior in the Intel® Quartus® Prime Pro Edition Software version 20.4 and earlier. Ensure the PMBus host adheres to the latest handshake flow available in the Intel® Stratix® 10/Intel Agilex® Power Management User Guide Intel® Stratix® 10 Power Management User Guide Intel Agilex ® Power Management User Guide
Custom Fields values:
['novalue']
Troubleshooting
22012583418
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
21.2
21.1
['Agilex™ 7 FPGAs and SoCs', 'Stratix® 10 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2023-03-12
external_document