How can I map registers to I/O elements (IOEs) through Synplify version 6.<I>x</I> and higher? - How can I map registers to I/O elements (IOEs) through Synplify version 6.<I>x</I> and higher?
Description Altera ® recommends that I/O cell register assignments are made in the Quartus ™ software. However, you can implement these assignments in Synplify as well using the syn_useioff attribute on a global or local basis. You can set this globally by setting syn_useioff=1 on the top level, directly in the source code, through the Synplify settings tool SCOPE, or directly in the constraint file. Table 1. Setting syn_useioff=1 Globally Programming Language Syntax Verilog HDL module test (d, clk, q) /*synthesis syn_useioff=1 */; VHDL architecture rtl of test is attribute syn_useioff : boolean; attribute syn_useioff of rtl: architecture is true; Constraint file define_global_attribute syn_useioff 1 Table 2. Setting syn_useioff=1 Locally Programming Language Syntax Verilog HDL module test (d, clk, q); input [3:0] d; input clk; output [3:0] q /*synthesis syn_useioff=1 */ reg q; ... VHDL entity test is port (d: in std_logic_vector [3 downto 0]; clk: in std_logic; q : out std_logic_vector[3 downto 0]; attribute syn_useioff : boolean; attribute syn_useioff of q : signal is true; end test; Constraint file define_attirbute {p:q[3:0]} syn_useioff 1