Why does SignalTap II Logic Analyzer display 'Program the device to continue' message even though the design was compiled with the latest SignalTap II file(.stp)? - Why does SignalTap II Logic Analyzer display 'Program the device to continue' message even though the design was compiled with the latest SignalTap II file(.stp)? Description Due to a problem in the Quartus® II software version 14.0 and later, you may see the message 'Program the device to continue' and the following error message when you run SignalTap™ II Logic Analyzer on a design which was compiled with old SignalTap II libraries located in the ./megafunctions folder. Error (261009): Cannot run SignalTap II Logic Analyzer. SignalTap II File is not compatible with the file programmed in your device. The expected compatibility checksum value is [SOF Checksum]; the value read from your device is 0xA1B2C3D4 Resolution To work around this problem, remove the ./megafunctions folder from your Quartus II project so that the Quartus II software uses correct version of the SignalTap II libraries. This problem is scheduled to be fixed in a future release of the Quartus II software. Custom Fields values: ['novalue'] Troubleshooting novalue False ['novalue'] ['FPGA Dev Tools Quartus II Software'] novalue 14.0 ['Programmable Logic Devices'] ['novalue'] ['novalue'] ['novalue'] - 2021-08-25