Incorrect Programming File Compatibility for EPCS and EPCQ to EPCQA Devices in AN 822: Intel Configuration Device Migration Guideline - Incorrect Programming File Compatibility for EPCS and EPCQ to EPCQA Devices in AN 822: Intel Configuration Device Migration Guideline Description Issue 522006, 522405 : Chapter Software Migration Guidelines, section Programming File Compatibility, version 2018.01.11 The compatibility information in “Table 3: Programming File Compatibility for EPCS and EPCQ to EPCQA Devices” was preliminary and incorrect. Resolution Tthe following table shows the updated Programming File Compatibility for EPCS and EPCQ to EPCQA devices: FPGA Device Family Original Configuration Device Configuration Device Density Programming Files supported Disable EPCS/EPCQ ID check Setting Compatible with EPCQA (1)(2) Legacy FPGA devices (Other devices than Cyclone® V, Arria® V or Stratix® V devices) EPCS 64Mb & below .pof/.jic/.rpd/.jam/.jbc Any Yes .svf Any Yes (8) 128Mb .pof/.jic/.rpd Any Yes (3) .svf Any Yes (8) .jam/.jbc Any No (4) EPCQ Any .pof/.jic/.rpd/.jam/.jbc On (5) Yes .svf On (5) Yes (8) Cyclone® V, Arria® V or Stratix® V devices EPCS 64Mb & below .pof/.jic/.rpd/.jam/.jbc On (6) Yes .svf On (6) Yes (8) 128Mb .pof/.jic/.rpd On (6) Yes (3) .svf On (6) Yes (8) .jam/.jbc Any No (4) EPCQ (7) Any Any Any No Notes: Note 1 : This table assumes other compatibility considerations are satisfied Note 2 : This table assumes the programming files do not contain any ASMI Parallel IP or Serial Flash Loader IP Note 3 : In .rpd file, the binary data is the same between EPCS128 and EPCQ128A. But due to different sector size, a proper erasing procedure is required when programming each device. Note 4 : Due to different sector size, the .jam/.jbc file is different between EPCS and EPCQ. Note 5 : Quartus II version 15.1 or later, automatic mode turns on this option automatically Note 6 : Other than Quartus II version 13.0 to 15.0, automatic mode turns on this option automatically Note 7 : EPCQ programming files are not compatible with EPCQ-A in AS x1 or AS x4 modes Note 8 : Only supported for svf files generated for EPCS devices that program an EPCQ-A, but not the other way around Custom Fields values: ['novalue'] Troubleshooting FB: 522006; True ['novalue'] ['FPGA Dev Tools Quartus® Prime Software Pro'] novalue 17.1 ['Programmable Logic Devices'] ['novalue'] ['Configuration Device EPCQ', 'Configuration Device EPCS', 'Configuration Devices', 'Configuration Device EPCQ', 'Configuration Devices'] ['novalue'] - 2021-08-25

external_document