How to Enable on chip termination for 3.3V LVCMOS? - How to Enable on chip termination for 3.3V LVCMOS? I'm using Cyclone V - 5CEFA4F23C8 and would like to enable the OCT on some of the pins (Location PIN_P16 for example). I'm using 3.3-V LVCMOS I/O standard. I get this error message: "I/O standard 3.3-V LVCMOS on I/O pin xxxx cannot have termination logic option setting series 40 ohm without calibration" Am I missing something or is OCT really unavailable for this standard/pin? Replies: Re: How to Enable on chip termination for 3.3V LVCMOS? Hello, Yes, that is correct. Thank you Replies: Re: How to Enable on chip termination for 3.3V LVCMOS? Thanks Amin. To be clear, since the LVCMOS 3.3 isn't listed in either of the tables 5-29 or 5-30, it means that OTCs aren't available, right? Replies: Re: How to Enable on chip termination for 3.3V LVCMOS? Hello, Please refer to page 144 of this document: https://www.intel.com/content/dam/www/programmable/us/en/pdfs/literature/hb/cyclone-v/cv_5v2.pdf Thank you - 2021-10-22