Qsys: You can directly connect a maximum of 32 slaves connected to a master - Qsys: You can directly connect a maximum of 32 slaves connected to a master
Description In Qsys, you can directly connect a maximum of 32 slaves connected to a master. Resolution If you need to connect more than 32 slaves, use pipeline bridges to reduce the number of slaves that are directly connected to a master.