Is there any known issue with Stratix® 10 FPGA Configuration via Protocol (CvP) operation in Quartus® Prime Pro Edition Software version 18.1? - Is there any known issue with Stratix® 10 FPGA Configuration via Protocol (CvP) operation in Quartus® Prime Pro Edition Software version 18.1? Description You may encounter the following failure when trying to perform the Configuration via Protocol (CvP) operation in Quartus® Prime Pro Edition Software version 18.1: When you perform any Configuration via Protocol operation, there is a small chance that the operation will halt. This issue impacts all Stratix® 10 FPGA production devices. During the Configuration via Protocol (CvP) process, if the bitstream is corrupted after the first 168kB of data, the CVP_CONFIG_ERROR bit in the CvP Status Register goes high. This will cause the Stratix® 10 FPGA device to hang, and another Configuration cannot recover it via a Protocol (CvP) update. This issue impacts all Stratix® FPGA 10 production devices. Resolution Power cycle the Stratix® FPGA device to perform the next Configuration via Protocol (CvP) operation. Custom Fields values: ['novalue'] Troubleshooting 1408179804 False ['novalue'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 18.1 18.1 ['Stratix® 10 FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2024-10-25