Why do F-Tile Serial Lite IV IP and F-Tile Interlaken IP designs fail hardware internal serial loopback testing with Quartus® Prime Pro Edition Software v22.4 Solution Patch 0.14? - Why do F-Tile Serial Lite IV IP and F-Tile Interlaken IP designs fail hardware internal serial loopback testing with Quartus® Prime Pro Edition Software v22.4 Solution Patch 0.14?
Description Due to a problem in the Quartus® Prime Pro Edition Software v22.4 Solution Patch 0.14, you might observe that F-Tile Serial Lite IV IP and F-Tile Interlaken IP designs have failures with internal serial loopback testing. This is because Patch 0.14 is not applicable for F-Tile Serial Lite IV IP and F-Tile Interlaken IP designs. Resolution To avoid this failure, you must use the Quartus® Prime Pro Edition Software version 22.4 without any patch applied. This problem is fixed beginning with the Quartus® Prime Pro Edition Software version 23.1.
Custom Fields values:
['novalue']
Troubleshooting
15012673654
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
23.1
22.4
['Agilex™ 7 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2025-06-10
external_document