Why does Signal Tap show "Program the device to continue" when using the JTAG-Over-Protocol IP to tap logic within a PR (Partial Reconfiguration) partition? - Why does Signal Tap show "Program the device to continue" when using the JTAG-Over-Protocol IP to tap logic within a PR (Partial Reconfiguration) partition? Description Due to a problem in the Quartus® Prime Pro Edition Software version 23.4 and earlier, the Signal Tap Logic Analyzer IP will show "Program the device to continue" when attempting to tap logic within a PR partition when also using the JTAG-Over-Protocol IP. Resolution To work around this problem, disable the Enable use of TCK-ENA option within the JTAG-Over-Protocol IP. This problem is scheduled to be fixed in a future release of Quartus® Prime Pro Edition Software. Custom Fields values: ['novalue'] Troubleshooting 13011461369 False ['Signal Tap Logic Analyzer IP'] ['FPGA Dev Tools Quartus® Prime Software Pro'] novalue 23.4 ['Agilex™ FPGA Portfolio', 'Stratix® 10 FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2025-06-03