Why does the Intel Agilex® 7 FPGA RSU fail to boot from the factory image after upgrading the factory image? - Why does the Intel Agilex® 7 FPGA RSU fail to boot from the factory image after upgrading the factory image?
Description Due to a problem in the Intel® Quartus® Prime Pro Edition Software versions 20.2 onwards, the RSU factory image is corrupted after upgrading the factory image in the Intel Agilex® 7 device. Resolution There is no workaround for the current problem because the RSU Factory Upgrade feature is broken. This problem was fixed starting with Intel® Quartus® Prime Pro Editon Software version 20.4
Custom Fields values:
['novalue']
Troubleshooting
1508295547
False
['Remote Update IP']
['FPGA Dev Tools Quartus® Prime Software Pro']
20.4
20.3
['Agilex™ 7 FPGAs and SoCs', 'Agilex™ 7 FPGA F-Series', 'Agilex™ 7 FPGA I-Series']
['novalue']
['Configuration Device EPCQ-L']
['novalue'] - 2023-03-22
external_document