Are there any problems if a floating voltage exists on the VCCL_GXB supply before it is ramped up on Cyclone IV GX devices? - Are there any problems if a floating voltage exists on the VCCL_GXB supply before it is ramped up on Cyclone IV GX devices? Description No, there is no problem if a floating voltage exists on the VCCL_GXB rail before it is ramped in Cyclone® IV GX devices. Leakage can occur between the VCCL_GXB and VCCH_GXB supplies which can cause VCCL_GXB to float to approximately 0.3V before the power supply is ramped up. This is expected behavior and will not cause functional or reliability failures. This can be observed if the VCCH_GXB supply is powered up before VCCL_GXB and the regulators were designed to leave the power supplies to float before they ramp up. Related Articles Are there any problems if a floating voltage exists on the VCCH_GXB supply rail before it is ramped in Cyclone IV GX devices? Custom Fields values: ['novalue'] Troubleshooting novalue False ['novalue'] ['novalue'] novalue novalue ['Cyclone® IV GX FPGA'] ['novalue'] ['novalue'] ['novalue'] - 2021-08-25