Why does the RX alignment lock remain low when simulating the E-Tile Hard IP for Ethernet in 100G with RS(528,514) FEC and 100G with RS(544,514) FEC design examples using the Synopsys* VCS* / VCS* MX simulation tools? - Why does the RX alignment lock remain low when simulating the E-Tile Hard IP for Ethernet in 100G with RS(528,514) FEC and 100G with RS(544,514) FEC design examples using the Synopsys* VCS* / VCS* MX simulation tools? Description When using the latest versions of the Synopsys* VCS* / VCS* MX simulator, RX alignment lock is remaining low for both the 100G with RS(528,514) FEC and the 100G with RS(544,514) FEC design examples of the E-Tile Ethernet Hard IP due to the presence of switch "-deraceclockdata" in the USER_DEFINED_ELAB_OPTIONS in the sim script file run_vcs .sh. This problem applies to E-Tile Ethernet Hard IP in both Stratix® 10 FPGA and Agilex™ 7 FPGA devices and is limited to the 100G Design Examples. Resolution To workaround this problem, remove the option " -deraceclockdata " from the USER_DEFINED_ELAB_OPTIONS in the sim script file run_vcs .sh located in the testbench simulation directory <design_example_dir>/example_testbench . This problem is planned to be fixed in a future release of the Quartus® Prime Pro Software Edition. Custom Fields values: ['novalue'] Troubleshooting 16027133533 False ['E-Tile Ethernet IP for Agilex™ 7 FPGA'] ['FPGA Dev Tools Quartus® Prime Software Pro'] novalue 25.1 ['Agilex™ 7 FPGAs and SoCs', 'Stratix® 10 FPGAs and SoCs'] ['novalue'] ['novalue'] ['Agilex™ 7 FPGA I-Series Dev Kit', 'Stratix® 10 SX FPGA Dev Kit', 'Stratix® 10 TX FPGA Signal Integrity Dev Kit'] - 2025-05-12