Can I recover from an Intel® Stratix® 10 CvP failure after an unsuccessful initial configuration? - Can I recover from an Intel® Stratix® 10 CvP failure after an unsuccessful initial configuration?
Description No, suppose an Intel® Stratix® 10 device is initially configured with a corrupted core image over Configuration via Protocol (CvP). In that case, a subsequent configuration attempt with a good core image will be seen to fail. Can I recover from an Intel® Stratix® 10 CvP failure after an unsuccessful initial configuration? Resolution To recover from the configuration failure, power cycle the Intel® Stratix® 10 device and then configure it with a good core image. This problem is planned to be fixed in a future release of the Intel Quartus® Prime Pro Edition Software.
Custom Fields values:
['novalue']
Troubleshooting
FB: 549472; 556231; HSD 2205690132;2205833135
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
19.1
18.0
['Stratix® 10 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2023-01-30
external_document