Why do I get fitter error message when selecting HDMI protocol option in the L-Tile and H-Tile fPLL Intel® Stratix® 10 FPGA IP? - Why do I get fitter error message when selecting HDMI protocol option in the L-Tile and H-Tile fPLL Intel® Stratix® 10 FPGA IP? Description Due to a problem in the Intel® Quartus® Prime Pro Edition software versions 19.1, 18.2, 18.1.1 and 18.1, when using the HDMI protocol option for fPLL IP, users will see the following fitter error message: Error(15653): The Fitter cannot find a legal configuration for the following atoms. Update any outdated transceiver PHY IP cores, correct any illegal pin assignments, and then recompile your design. Error(15744): In atom 'u0|xcvr_fpll_s10_htile_0|fpll_inst' Error(15744): The settings must match one or more of these conditions: Error(15744): ( primary_use != TX ) OR ( side == LEFT ) OR ( f_min_pfd == 50000000 ) Error(15744): But the following assignments violate the above conditions: Error(15744): side = SIDE_OFF Error(15744): f_min_pfd = 25000000 Error(15744): primary_use = TX The HDMI protocol option is not supported for the Intel® Quartus® Prime Pro Edition software versions 19.1, 18.2, 18.1.1 and 18.1. Resolution This problem is fixed in Intel® Quartus® Prime Pro Edition software version 19.2. For Intel® Quartus® Prime Pro versions prior to 19.2, use Basic protocol mode. Custom Fields values: ['novalue'] Troubleshooting 1409059605 False ['novalue'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 19.2 18.1 ['Stratix® 10 FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2021-08-25