Why can't I configure my Intel® Stratix® 10 device using a . JAM file? - Why can't I configure my Intel® Stratix® 10 device using a . JAM file?
Description Due to a problem beginning with the Intel® Quartus® Prime Pro software version 17.1, you may not be able to configure an Intel® Stratix® 10 device with a . JAM file. This problem is seen both when using the JAM™ STAPL Player and the Quartus JLI utility to configure the device. You might see the following failure message when using the Quartus®JLI utility: Error status: Request failed CONF_DONE pin failed to go high at device #1 No response from device Exit code = 23... No response from device Resolution To work around this problem, regardless of whether you see the above error, click on the following link to download a patch for Intel® Quartus® Prime Pro Edition Software version 17.1.1. Download patch This problem is fixed starting with the Intel® Quartus® Prime Pro Edition Software version 18.0.
Custom Fields values:
['novalue']
Troubleshooting
2205659874
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
18.0
17.1.1
['Stratix® 10 FPGAs and SoCs']
['Altera® FPGA Programming Software']
['novalue']
['novalue'] - 2023-03-29
external_document