Why does the Intel® Quartus® Prime software fails to detect a floating license? - Why does the Intel® Quartus® Prime software fails to detect a floating license?
Description In the Intel® Quartus® Prime software version 16.1 and later, you may see that your floating license is not detected. This occurs on slower connections between the license server and the client. The Flexlm version was upgraded to 11.13 and this version is intolerant to WAN latency. Resolution To work around this problem, adjust the FLEXLM_TIMEOUT environment variable in the client machine, the available range is from 0 to 2,147,483,647 microseconds. Default value is 100 microseconds. For example to set the variable to 1 second, set the variable as follows: FLEXLM_TIMEOUT=100000000
Custom Fields values:
['novalue']
Troubleshooting
FB: 417298;
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
novalue
16.1
['Programmable Logic Devices']
['novalue']
['novalue']
['novalue'] - 2021-08-25
external_document