Why is the dummy RX PHY required for reconfiguration missing from the Intel® FPGA SDI II IP generated Multi Rate Bidirectional mode design example? - Why is the dummy RX PHY required for reconfiguration missing from the Intel® FPGA SDI II IP generated Multi Rate Bidirectional mode design example?
Description Due to a problem with the Intel® FPGA SDI II IP in Intel® Quartus® Prime Pro software version 17.1, you may observe that the dummy RX PHY required for reconfiguration is missing from the IP generated Multi Rate Bidirectional mode design example targetting Intel® Stratix® 10 devices. This problem affects Windows* OS configurations only. Resolution To work around this problem, generate the design example in Linux* OS. This problem has been fixed starting in Intel Quartus Prime Pro software version 17.1.2.
Custom Fields values:
['novalue']
Troubleshooting
FB: 529919;
True
['SDI II IP']
['FPGA Dev Tools Quartus® Prime Software Pro']
17.1.2
17.1
['Stratix® 10 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2021-08-25
external_document