Why does the received data mismatch the transmitted data from the external source with the GTS CPRI PHY IP? - Why does the received data mismatch the transmitted data from the external source with the GTS CPRI PHY IP?
Description Due to a problem in the Quartus® Prime Pro Edition software version 24.3.1, the GTS CPRI PHY IP has a problem where the data received on the CPRI RX side may not match what was sent from the external source. Instead, the data received on the RX side is always identical to what was transmitted from the CPRI TX side. Resolution There is no workaround for this problem in the Quartus® Prime Pro Edition software version 24.3.1 and earlier. This problem is fixed beginning with the Quartus Prime Pro Edition software version 25.1.