Why does the INSERT_SAFE_SEU_ERROR command inject the SEU error into an incorrect location on Agilex™ 3 FPGA devices? - Why does the INSERT_SAFE_SEU_ERROR command inject the SEU error into an incorrect location on Agilex™ 3 FPGA devices?
Description Due to a problem with the Quartus® Prime Pro Edition Software version 25.3, injecting an SEU error using the INSERT_SAFE_SEU_ERROR command on Agilex™ 3 FPGA devices may result in the READ_SEU_ERROR command reporting a location that does not match the predefined injection location. This incorrect SEU error location could potentially lead to functional errors in user designs. Resolution This problem is scheduled to be fixed in a future release of the Quartus® Prime Pro Edition Software.
Custom Fields values:
Troubleshooting
15018465925
['FPGA Dev Tools Quartus® Prime Software']
25.3 - 2025-10-14
external_document