Why does Intel Agilex® 7 FPGA fail with fitter error while accessing HPS EMIF IP DDR5 2x32 with/without ECC configuration with Memory devices support other than Discrete in Intel® Quartus® Prime Pro Edition Software version 23.2? - Why does Intel Agilex® 7 FPGA fail with fitter error while accessing HPS EMIF IP DDR5 2x32 with/without ECC configuration with Memory devices support other than Discrete in Intel® Quartus® Prime Pro Edition Software version 23.2?
Description Intel® Quartus® Prime Pro Edition Software version 23.2 does not support Intel Agilex® 7 HPS EMIF IP DDR5 2x32 with/without ECC configuration in Memory devices UDIMM, RDIMM, LRDIMM, SODIMM in Intel® Quartus® Prime Pro Edition Software version 23.2 Resolution Intel Agilex® 7 HPS EMIF IP DDR5 2x32 with/without ECC configuration in Memory devices UDIMM, RDIMM, LRDIMM, SODIMM is available beginning with Intel® Quartus® Prime Pro Edition Software version 23.3
Custom Fields values:
['novalue']
Troubleshooting
22018420547
False
['External Memory Interfaces (EMIF) IP']
['FPGA Dev Tools Quartus® Prime Software']
23.3
23.2
['Agilex™ 7 FPGA M-Series']
['Altera® FPGA Programming Software']
['novalue']
['novalue'] - 2023-12-26
external_document