Error: The dynamic chainout feature for fixed-point DSP is an advanced feature not supported in the current release. Disconnect the disable_chainout port and contact Altera for details. - Error: The dynamic chainout feature for fixed-point DSP is an advanced feature not supported in the current release. Disconnect the disable_chainout port and contact Altera for details.
Description This error message will be seen during compilation when using the Primitive DSP Native Fixed Point DSP Agilex™ FPGA IP and the "Enable disable_chainout " option is enabled. This problem only affects the Agilex™ 5 and Agilex™ 7 devices. Resolution To work around this problem, disconnect the disable_chainout port by setting parameter “ Enable disable_chainout ” to “ No ” in Native Fixed Point DSP Intel Agilex™ FPGA IP. Recompile on your design in the Quartus® Prime Pro Edition Software version 24.3 or later. Or, download and install patch for your Quartus® Prime Pro Edition Software version and recompile your design. Download and install Patch 0.00dsp for 23.1 from the appropriate link below: Download the version 23.1 patch 0.00dsp for Windows (.exe) Download the version 23.1 patch 0.00dsp for Linux (.run) Download the Readme for Patch 0.00dsp for Quartus® Prime Pro Edition Software version 23.1 (.txt) Download and install Patch 0.00dsp for 23.2 from the appropriate link below: Download the version 23.2 patch 0.00dsp for Windows (.exe) Download the version 23.2 patch 0.00dsp for Linux (.run) Download the Readme for Patch 0.00dsp for Quartus® Prime Pro Edition Software version 23.2 (.txt) Download and install Patch 0.00dsp for 23.3 from the appropriate link below: Download the version 23.3 patch 0.00dsp for Windows (.exe) Download the version 23.3 patch 0.00dsp for Linux (.run) Download the Readme for Patch 0.00dsp for Quartus® Prime Pro Edition Software version 23.3 (.txt) Download and install Patch 0.00dsp for 23.4 from the appropriate link below: Download the version 23.4 patch 0.00dsp for Windows (.exe) Download the version 23.4 patch 0.00dsp for Linux (.run) Download the Readme for Patch 0.00dsp for Quartus® Prime Pro Edition Software version 23.4 (.txt) Download and install Patch 0.00dsp for 24.1 from the appropriate link below: Download the version 24.1 patch 0.00dsp for Windows (.exe) Download the version 24.1 patch 0.00dsp for Linux (.run) Download the Readme for Patch 0.00dsp for Quartus® Prime Pro Edition Software version 24.1 (.txt) Download and install Patch 0.00dsp for 24.2 from the appropriate link below: Download the version 24.2 patch 0.00dsp for Windows (.exe) Download the version 24.2 patch 0.00dsp for Linux (.run) Download the Readme for Patch 0.00dsp for Quartus® Prime Pro Edition Software version 24.2 (.txt) For Agilex™ 7 and Agilex™ 5 design developed in Quartus® Prime Pro Edition Software prior to version 24.3, you may run the risk assessment script to check if your design is impacted. Steps to run the script: Run EDA Netlist Writer with the successfully pre-compiled design. Insert the risk assessment script in the Quartus project folder Navigate to the Quartus project folder: cd <quartus project path> Run the command: tclsh screening.tcl ./simulation/questa/<project_name>.vo Follow the message prompted for next step. For deployed designs with dynamic chainout enabled in the field, contact Altera by filing IPS case (stating bug ID 15017127180) for further queries.
Custom Fields values:
['novalue']
Troubleshooting
14022525781
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
No plan to fix
24.3
['Agilex™ FPGA Portfolio']
['novalue']
['novalue']
['novalue'] - 2024-12-11
external_document