Why is the GTS PMA/FEC Direct PHY IP not getting configured with the provided Presets and showing errors? - Why is the GTS PMA/FEC Direct PHY IP not getting configured with the provided Presets and showing errors? Description Due to a problem in the Quartus® Prime Pro Edition Software version 24.3.1, using either of the two presets shown below with the GTS PMA/FEC Direct PHY IP will generate an error message while being used for configuration. S.No. PMA/FEC Direct Presets Description 1 FECDirect_10G_1_Lane_System_PLL_FirecodeFEC One FEC Direct GTS lane, operating at 10.3125 Gbps with system PLL clocking mode (Firecode FEC enabled) 2 PMADirect_6G_2_System_PLL_Custom_Cadence Two PMA Direct GTS lanes, operating at 3.4 Gbps per lane, with system PLL clocking mode (Custom cadence enabled) The issue is limited to only these two preset configurations. Resolution This problem is planned to be fixed in a future release of the Quartus® Prime Pro Edition Software. Custom Fields values: ['novalue'] Troubleshooting 16026491552 True ['Interfaces'] ['FPGA Dev Tools Quartus® Prime Software Pro'] No plan to fix 24.3.1 ['Agilex™ 5 FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2025-02-02