Critical Warning (184043): Fitter was unable to find transceiver reconfiguration controllers - Critical Warning (184043): Fitter was unable to find transceiver reconfiguration controllers
Description You may see this Quartus® II critical warning if you turn off the PROJECT_SHOW_ENTITY_NAME setting and your Stratix® V, Arria® V, or Cyclone® V design includes transceivers. The PROJECT_SHOW_ENTITY_NAME setting is mandatory for the transceiver Reconfiguration Controller IP to work correctly. Resolution Turn on the PROJECT_SHOW_ENTITY_NAME assignment in the assignment editor.
Custom Fields values:
['novalue']
Troubleshooting
119145
False
['novalue']
['novalue']
novalue
novalue
['Arria® V FPGAs and SoCs', 'Cyclone® V FPGAs and SoCs', 'Stratix® V GS FPGA', 'Stratix® V GT FPGA', 'Stratix® V GX FPGA']
['novalue']
['novalue']
['novalue'] - 2023-03-29
external_document