Why do I see the Errors in data transmission of the GTS PMA/FEC Direct PHY FPGA IP for PMA configuration rules set to CPRI with Fiber Channel RS(528,514) Forward Error Correction (FEC) enabled? - Why do I see the Errors in data transmission of the GTS PMA/FEC Direct PHY FPGA IP for PMA configuration rules set to CPRI with Fiber Channel RS(528,514) Forward Error Correction (FEC) enabled?
Description Due to a problem in the Quartus® Prime Pro Edition Software version 24.2, when using the GTS PMA/FEC Direct PHY FPGA IP with the configurations shown below, errors will be observed in data transmission, PMA configuration rules --> CPRI FEC mode --> Fiber Channel (FC) RS(528,514) Forward Error Correction (FEC) Data Rate --> 10G Resolution This problem is fixed in 24.3.1 release of the Quartus® Prime Pro Edition Software.
Custom Fields values:
['novalue']
Troubleshooting
15015538184
True
['Interfaces']
['FPGA Dev Tools Quartus® Prime Software Pro']
24.3.1
24.2
['Agilex™ 5 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2025-06-26
external_document