Is there a known issue with generating a Comma-Separated Value (.csv) file for the Early Power Estimator (EPE) tool in the Quartus® II software version 13.0sp1 and earlier for Cyclone® V SoC devices? - Is there a known issue with generating a Comma-Separated Value (.csv) file for the Early Power Estimator (EPE) tool in the Quartus® II software version 13.0sp1 and earlier for Cyclone® V SoC devices?
Description Yes, there is a known issue with generating an Early Power Estimator .csv file in the Quartus® II software version 13.0sp1 and earlier for Cyclone® V SoC devices. When the .csv file is imported into the EPE tool, the I/O power for the Hard Processor System (HPS) functions is counted in both the HPS and FPGA I/O sections of the EPE tool, resulting in higher estimated power than expected. The HPS I/O power should only be accounted for in the HPS section of the EPE tool. Resolution This is fixed in the Quartus II software v13.1.
Custom Fields values:
['novalue']
Troubleshooting
1408035543
False
['novalue']
['FPGA Dev Tools Quartus II Software']
13.1
13.1
['Cyclone® V SE FPGA', 'Cyclone® V ST FPGA', 'Cyclone® V SX FPGA']
['novalue']
['novalue']
['novalue'] - 2023-03-13
external_document