Why does Quartus® Prime Pro Edition Software Fitter report a VCCIO_PIO_SDM voltage for Agilex™ 7 FPGA devices that differs from the 3A bank voltage? - Why does Quartus® Prime Pro Edition Software Fitter report a VCCIO_PIO_SDM voltage for Agilex™ 7 FPGA devices that differs from the 3A bank voltage? Description According to the Agilex™ 7 FPGA Device Family Pin Connection Guidelines, the 3A bank power supply and VCCIO_PIO_SDM should be connected. However, due to a problem in the Quartus® Prime Pro Edition Software, the Fitter .pin report will correctly report the voltage of the 3A bank. Still, the voltage of VCCIO_PIO_SDM does not match it. Resolution You should follow the Agilex™ 7 FPGA Device Family Pin Connection Guidelines in accordance with the conditions of your design. Custom Fields values: ['novalue'] Troubleshooting 14017297799 False ['novalue'] ['FPGA Dev Tools Quartus® Prime Software Pro'] No plan to fix 22.2 ['Agilex™ 7 FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2025-06-02