Intel Agilex® Configuration User Guide - Remote System Update (RSU) - Figure 85. Remove Application Image is incorrect - Intel Agilex® Configuration User Guide - Remote System Update (RSU) - Figure 85. Remove Application Image is incorrect
Description Figure 85. Remove Application Image, in section 5.6.6 Removing an Application Image, in the Intel Agilex® 7 FPGA Configuration User Guide is incorrect: UG-20205 ID: 683673 Version 2022.12.05 5.6.6. Removing an Application Image Resolution Incorrect information in Figure 85: % qspi_write_one_word 0x002ec028 0x004A8028. Correct information is: %qspi_write_one_word 0x004A8028 0x00000000. The correct figure should look like the image shown below: % qspi_write_one_word 0x004A0028 0x00000000 % qspi_write_one_word 0x004A8028 0x00000000 This updated information has been added in the Intel Agilex® 7 FPGA Configuration User Guide version 2023.04.28.
Custom Fields values:
['novalue']
Troubleshooting
15013049384
False
['novalue']
['novalue']
novalue
novalue
['Agilex™ 7 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2023-04-17
external_document
- Resource Type
- Support Resources > Knowledge Articles
- Source Name
- khoros