Why does SDI II Intel® FPGA IP multi-rate or triple-rate design example fail to work with the Intel Agilex® 7 device when using the Intel® Quartus® Prime Pro Edition Software version 22.3? - Why does SDI II Intel® FPGA IP multi-rate or triple-rate design example fail to work with the Intel Agilex® 7 device when using the Intel® Quartus® Prime Pro Edition Software version 22.3?
Description Due to a problem in Intel® Quartus® Prime Pro Edition Software version 22.3 on the Windows* platform, the SDI II Intel® FPGA IP multi-rate or triple-rate design example fail to generate with the Intel Agilex® 7 device due to an issue with the F-Tile PMA/FEC Direct PHY Multirate Intel® FPGA IP. The following error message will appear: Error: Error starting the process ([sh, -c, (cd ../../directphy_f/source/&& ls *)]): Cannot run program “sh” (in directory “C:\intelFPGA_pro\22.3\ip\altera\alt_xcvr\altera_xcvr_native_phy\directphy_f_sr_wrapper\tcl”): CreateProcess error=2, The system cannot find the file specified Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 22.3 on both Windows* and Linux platforms, no SDI II video output is displayed on the receiver side when using the SDI II Intel® FPGA IP multi-rate or triple-rate designs on the Intel® Agilex™ F-tile devices. This issue impacts all SDI II Intel® FPGA IP design examples that support dynamic reconfiguration. Resolution A patch is available to fix both problems for the Intel® Quartus® Prime Pro Edition Software version 22.3. Download and install Patch 0.19 from the appropriate link below.: Download the patch Intel® Quartus® Prime Pro Edition version 22.3 Patch 0.19 for Windows (.exe) Download the Readme for Intel® Quartus® Prime Pro Edition version 22.3 Patch 0.19 (.txt) Linux installations do not require patch 0.19. Download and install Patch 0.09 from the appropriate link below.: Download the patch Intel® Quartus® Prime Pro Edition version 22.3 Patch 0.09 for Windows (.exe) Download the patch Intel® Quartus® Prime Pro Edition version 22.3 Patch 0.09 for Linux (.run) Download the Readme for Intel® Quartus® Prime Pro Edition version 22.3 Patch 0.09 (.txt) This problem has been fixed starting with the Intel® Quartus® Prime Pro Edition Software version 22.4.
Custom Fields values:
['novalue']
Troubleshooting
14016675499, 15010939037
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
22.4
22.1
['Agilex™ 7 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2023-06-01
external_document