Error: Internal Error: Sub-system: SIN, File: /quartus/tsm/sin/sin_micro_tnodes_utility.cpp, Line: 431 - Unknown I/O cell name: 'dibss' - Error: Internal Error: Sub-system: SIN, File: /quartus/tsm/sin/sin_micro_tnodes_utility.cpp, Line: 431 - Unknown I/O cell name: 'dibss'
Description Due to a problem in the Intel® Quartus® Prime Pro Edition software version 20.3, you may see this error due to unrecognised and unbypassed new pins added in Direct Interface Bus (DIB) IP Intel® pins for IO timing during compilation in Intel® Stratix®10 devices. Resolution A patch is available to workaround this problem for the Intel® Quartus® Prime Pro Edition software version 20.3. Download and install Patch 0.46pro from the appropriate link below. Download patch Intel® Quartus® Prime Pro Edition 20.3 Patch 0.46pro for Windows (.exe) Download patch Intel® Quartus® Prime Pro Edition 20.3 Patch 0.46pro for Linux (.run) Download the Readme for Intel® Quartus® Prime Pro Edition 20.3 Patch 0.46pro (.txt) This problem is fixed beginning with the Intel® Quartus® Prime Pro Edition software version 21.1
Custom Fields values:
['novalue']
Troubleshooting
1508628925
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
21.1
20.3
['Stratix® 10 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2022-01-18
external_document