Error: System.DUT.config_tl/APPS.config_tl: Signal tl_cfg_sts has width 73 on DUT.config_tl, but has width 123 on APPS.config_tl - Error: System.DUT.config_tl/APPS.config_tl: Signal tl_cfg_sts has width 73 on DUT.config_tl, but has width 123 on APPS.config_tl Description In Arria® V and Cyclone® V Hard IP for PCI Express reference designs, if you set the parameter 'Number of functions' to a value greater than one in the APPS (Altera's DMA) component, Qsys will report the following error messages. Error: System.DUT.config_tl/APPS.config_tl: Signal tl_cfg_sts has width 73 on DUT.config_tl, but has width 123 on APPS.config_tl. Error: System.DUT.config_tl/APPS.config_tl: Signal cpl_pending has width 3 on DUT.config_tl, but has width 8 on APPS.config_tl. Resolution While Arria® V and Cyclone® V Hard IP for PCI Express cores support multi-function, the APPS component has a DMA engine that does not support multi-function. This issue will not be fixed. Custom Fields values: ['novalue'] Troubleshooting 84640 False ['Arria® V Hard IP for PCI Express IP'] ['FPGA Dev Tools Quartus II Software'] No plan to fix 11.1 ['Arria® V GT FPGA', 'Arria® V GX FPGA', 'Arria® V ST FPGA', 'Arria® V SX FPGA', 'Cyclone® V GT FPGA', 'Cyclone® V GX FPGA', 'Cyclone® V ST FPGA', 'Cyclone® V SX FPGA'] ['novalue'] ['novalue'] ['novalue'] - 2023-03-30