Why does SEU fault injection fail after CvP update configuration on all Intel Agilex® devices? - Why does SEU fault injection fail after CvP update configuration on all Intel Agilex® devices? Description Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 22.1 and earlier, performing single event upset (SEU) fault injection might fail after the second CvP update on all Intel Agilex®devices. When the FPGA is configured with a periphery image and followed by the CvP update, the fault injection works as expected. You might observe fault injection failure if you do a subsequent CvP update. Resolution To work around this problem, you need to power cycle the device. Reconfiguration will not fix the problem. This problem is fixed starting with the Intel® Quartus® Prime Pro Edition Software version 22.2. Custom Fields values: ['novalue'] Troubleshooting 15010818982 False ['novalue'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 22.2 22.1 ['Agilex™ 7 FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2023-02-28