Simulation of Arria 10 Designs With Abstract PHY May Hang Under Certain Circumstances - Simulation of Arria 10 Designs With Abstract PHY May Hang Under Certain Circumstances
Description If you run an abstract PHY simulation with a reset duration of less than 100ns on global_reset_n , the simulation may hang and fail to complete. This problem is independant of the targeted external memory protocol, the particular IP configuration, or the simulator in use. Resolution The workaround for this problem is to reduce the reset duration to less than 100ns. This problem is fixed in version 15.1.1.
Custom Fields values:
['novalue']
Troubleshooting
novalue
True
['Simulation']
['FPGA Dev Tools Quartus® Prime Software Pro']
15.1.1
15.1
['Arria® 10 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2021-08-25
external_document