How can I check the results of the RAM bit Reservation settings in Cyclone III designs? - How can I check the results of the RAM bit Reservation settings in Cyclone III designs? Description To check the results of the RAM bit reservation settings in Cyclone ® III designs, follow these steps: 1. Locate the RAM in the Resource Property Editor 2. Check the Connectivity View. For the Input Ports, the disabled bitlines are named in the Signal Name column as |<ram instance name>|~QUARTUS_CREATED_GND_I . For the Output Ports, the disabled bitlines are named in the Signal Name column as |<ram instance name>|~QUARTUS_CREATED_GND~I~FITTER_CREATED_DUMMY_SLICE |<ram instance name>|~QUARTUS_CREATED_GND~I~FITTER_CREATED_DUMMY_SLICE_<n> Figure 1 Input port Figure 2 Output port Resolution Related Articles How do I resolve the M9K memory block read issue in Cyclone III devices using the Quartus II software solution? Custom Fields values: ['novalue'] Troubleshooting novalue False ['novalue'] ['FPGA Dev Tools Quartus II Software'] novalue 10.0 ['Cyclone® III FPGAs'] ['novalue'] ['novalue'] ['novalue'] - 2021-08-25