Why are the F-tiles in the Agilex™ 7 FPGA and SoC device unresponsive for my design compiled with the Quartus® Prime Pro Edition Software version 23.1 on the Windows* OS? - Why are the F-tiles in the Agilex™ 7 FPGA and SoC device unresponsive for my design compiled with the Quartus® Prime Pro Edition Software version 23.1 on the Windows* OS? Description Due to a problem in the Quartus® Prime Pro Edition Software version 23.1, F-tiles in the Agilex™ 7 FPGA and SoC devices are not correctly configured when the Quartus® Prime Pro Edition Software project is compiled using the Windows* OS, and the Quartus® Prime Pro Edition Software is installed on a different drive than where the project is located. Resolution To work around this problem, download and install patch 0.15 for the Quartus® Prime Pro Edition Software version 23.1 and recompile your design: Patch 0.15 for the Quartus® Prime Pro Edition Software version 23.1 for Windows (.exe) Readme for Patch 0.15 for the Quartus® Prime Pro Edition Software for Windows (.txt) This problem is fixed beginning with the Quartus® Prime Pro Edition Software version 23.2. Custom Fields values: ['novalue'] Troubleshooting 14019223526, 14019329938 False ['novalue'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 23.2 23.1 ['Agilex™ 7 FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2024-11-20