When using the IOPLL clock switchover feature in Intel Agilex® devices, must inclk1 be in the same I/O bank as the IOPLL? - When using the IOPLL clock switchover feature in Intel Agilex® devices, must inclk1 be in the same I/O bank as the IOPLL?
Description Yes, when using the IOPLL clock switchover feature in Intel Agilex® 7 devices, the secondary inclk1 input can only be sourced from dedicated clock inputs that are in the same I/O bank as the IOPLL. This restriction does not apply to inclk0 - only inclk1 . Resolution The Intel Agilex® 7 FPGA Clocking and PLL User Guide will be updated in a future release to include this information.
Custom Fields values:
['novalue']
Troubleshooting
18018036115, 14015361503
False
['novalue']
['novalue']
novalue
novalue
['Agilex™ 7 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2023-02-28
external_document