SDM Monitoring & Thermal Behavior - SDM Monitoring & Thermal Behavior
Are SDM-based voltage and temperature measurements accessible before FPGA configuration is complete? Is it expected that the temperature reported by the SDM in region 0 (where the SDM is located) is higher than in other regions , even under similar conditions?
Replies:
Re: SDM Monitoring & Thermal Behavior
Hi Farabi, all good thank you
Replies:
Re: SDM Monitoring & Thermal Behavior
Helo sbj, Do you have further question? regards, Farabi
Replies:
Re: SDM Monitoring & Thermal Behavior
Better to use the PTA now instead: https://docs.altera.com/r/docs/865226/current
Replies:
Re: SDM Monitoring & Thermal Behavior
Hello, Voltage/temperature measurement only accessible once the FPGA passed configuration and successfully enter user mode. It depends on your design and when you compare the temperature- if you are running the design with high speed IOs, the region which transceivers are located will show higher temperature/current consumption. If the FPGA sitting idle without running anything, you will see the VCC(including SDM) is higher than other region. you may want to get reference from PTC for your design. link : https://docs.altera.com/r/docs/814008/24.3/thermal-design-user-guide-agilextm-5-fpgas-and-socs/power-and-thermal-calculator-ptc regards, Farabi - 2026-06-13