Why are the Tx Equalization values displayed in Transceiver Toolkit different than the values applied in the .qsf of my Agilex™ 7 F-Tile transceiver design? - Why are the Tx Equalization values displayed in Transceiver Toolkit different than the values applied in the .qsf of my Agilex™ 7 F-Tile transceiver design?
Description Due to a problem in the Quartus® Prime Pro Edition Software version 22.4 and earlier, the txeq_pre_tap_2 , txeq_pre_tap_1 , txeq_main_tap , and txeq_post_tap_1 values shown in Transceiver Toolkit may be different than the values applied in the .qsf . Resolution This problem is fixed beginning with the Quartus® Prime Pro Edition Software version 23.1.
Custom Fields values:
['novalue']
Troubleshooting
14017784427
False
['F-Tile PMA/FEC Direct PHY IP']
['FPGA Dev Tools Quartus® Prime Software Pro']
23.1
22.3
['Agilex™ 7 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2023-12-21
external_document