Error(12418): Termination logic option is set to Series 50 Ohm without Calibration for output pin <pin name>~pad, but setting is not supported by I/O standard 3.0-V LVCMOS - Error(12418): Termination logic option is set to Series 50 Ohm without Calibration for output pin <pin name>~pad, but setting is not supported by I/O standard 3.0-V LVCMOS
Description Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 22.1, this error may occur when 3VIO and HPS IP are used simultaneously for designs targeting Intel® Stratix10® devices because "OUTPUT_TERMINATION OFF" assignment is missed to be enabled. Resolution To work around this problem in the Intel® Quartus® Prime Pro Edition Software version 22.1, add the . qsf assignment "set_instance_assinment -name OUTPUT_TERMINATION OFF -to <pin>" for failed pins. This problem has been fixed in the Intel® Quartus® Prime Pro Edition Software version 22.2.
Custom Fields values:
['novalue']
Troubleshooting
15010836332
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
22.2
22.1
['Stratix® 10 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2023-03-15
external_document