Why does the Intel® FPGA Power and Thermal Calculator (PTC) show invalid import value for transceiver (XCVR) Die ID in Intel Agilex® 7 devices? - Why does the Intel® FPGA Power and Thermal Calculator (PTC) show invalid import value for transceiver (XCVR) Die ID in Intel Agilex® 7 devices?
Description Due to a problem in the Intel® FPGA Power and Thermal Calculator (PTC) version 21.2 and earlier, you might see the transceiver Die ID had an invalid import value of HSSI_0_1 field defaulted to a value of HSSI_0_0 when importing .qptc file. The Intel® FPGA Power and Thermal Calculator (PTC) version 21.2 for Intel Agilex® 7 will produce an error message for importing the .qptc file. The input field "XCVR Die ID" had an invalid import value of " HSSI_0_1 ". The field was defaulted to a value of " HSSI_0_0 " instead. Resolution To work around this problem, correct the setting manually by setting the field values to HSSI_0_1 where appropriate. This problem is fixed starting with the Intel® FPGA Power and Thermal Calculator (PTC) of the Intel® Quartus® Prime Pro Edition Software version 21.3.
Custom Fields values:
['novalue']
Troubleshooting
22012954318
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
21.3
21.2
['Agilex™ 7 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2023-03-16
external_document